Queries, comments, suggestions? Please contact us.



Area Equipment for explosive atmospheres / Intrinsically safe and associated intrinsically safe electrical apparatus "i"

IEV ref 426-11-38

Symbol
Lc

en
maximum cable inductance
maximum inductance of the interconnecting cable that can be connected into an intrinsically safe circuit without invalidating intrinsic safety

fr
inductance maximale du câble, f
inductance maximale du câble d'interconnexion qui peut être raccordé à un circuit de sécurité intrinsèque sans invalider la sécurité intrinsèque

ar
اقصى محاثة لكابل

de
maximale Kabelinduktivität, f

es
máxima inductancia del cable, f

it
massima induttanza del cavo

ja
最大ケーブルインダクタンス

no
nb maksimal kabelinduktans

no
nn maksimal kabelinduktans

pl
maksymalna indukcyjność kabla lub przewodu, f

pt
indutância de cabo máxima
indutividade de cabo máxima

ru
максимальная индуктивность кабеля

zh
最大电缆电感

Publication date: 2020-03
Copyright © IEC 2024. All Rights Reserved.