Queries, comments, suggestions? Please contact us.



Area Risk assessment / Safety and risk reduction

IEV ref 903-01-16

en
malfunction
situation for which the electrical equipment does not perform the intended function due to a variety of reasons, including:
  • variation of a property or of a dimension of the processed material or of the work piece;
  • failure of one (or more) of its component parts or services;
  • external disturbances (e.g. shocks, vibration, electromagnetic interference);
  • design error or deficiency (e.g. software errors);
  • disturbance of its power supply;
  • surrounding conditions (e.g. condensation due to temperature change).

[SOURCE: IEC Guide 116:2010, 3.9]


fr
dysfonctionnement, m
situation dans laquelle l'équipement électrique n'assure pas la fonction prévue pour différentes raisons, parmi lesquelles:
  • variation d'une propriété ou d'une dimension du matériau traité ou de la pièce à usiner;
  • défaillance d'un (ou de plusieurs) de ses composants ou services;
  • perturbations d'origine extérieure (par exemple des chocs, des vibrations, des brouillages électromagnétiques);
  • erreur ou déficit de conception (par exemple erreurs logicielles);
  • perturbation de son alimentation électrique;
  • conditions d'environnement (par exemple condensation due à une variation de température).

[SOURCE: IEC Guide 116:2010, 3.9]


de
Fehlfunktion, f

es
mal funcionamiento

ko
오동작
오기능

ja
機能不良
機能不全

nl
be storing, f

pl
zakłócenie w działaniu, n

pt
disfuncionamento

sr
неисправност , ж јд

zh
功能失常

Publication date: 2013-06
Copyright © IEC 2024. All Rights Reserved.