PROPERTY |

Code: | 
0112/2///61360_4#AAE584 |

Version: | 
001 |

Revision: | 
05 |

IRDI: | 
0112/2///61360_4#AAE584#001 |

Preferred name: | 
grid 2 voltage for cut-off |

Synonymous name: | 
|

Symbol: | 
Vg2(co) |

Synonymous symbol: | 
|

Short name: | 
V_g2(co) |

Definition: | 
value as specified by level (minmax) of the direct voltage on grid 2 with respect to grid 1 for visual extinction of the focused spot of a colour display tube at maximum cathode voltage |

Note: | 
|

Remark: | 
Adjustment procedure: With all cathodes at maximum voltage, Vg2 is increased to a value at which one of the colours becomes just visible. Then the cathode voltages of the remaining guns are decreased until the other colours also become visible. |

Primary unit: | 
V |

Alternative units: | 
|

Level: | 
minMax |

Data type: | 
LEVEL(MIN,MAX) OF REAL_MEASURE_TYPE
|

Format: | 
NR2 S..3.3 |

Property constraint: | 
|

Definition source: | 
|

Property data element type: | 
NON_DEPENDENT_P_DET |

Drawing: | 
|

Formula in text: | 
|

Value list code: | 
|

Value list: | 
|

DET class: | 
E06 - electric potential, potential difference, tension, electromotive force |

Applicable classes: | 
0112/2///61360_4#AAA140 - colour display tube |

Definition class: | 
0112/2///61360_4#AAA001 |

Code for unit: | 
0112/2///62720#UAA296 - volt |

Codes for alternative units: | 
|

Code for unit list: | 
|

Status level: | 
Standard |

Is deprecated: | 
|

Published in: | 
IEC 61360-4 |

Published by: | 
IEC |

Proposal date: | 
2015-08-17 |

Version initiation date: | 
1996-08-01 |

Version release date: | 
2011-08-31 |

Revision release date: | 
2015-08-17 |

Obsolete date: | 
|

Responsible Committee: | 
SC3D |

Conditions: | 
-
|

Change request ID: | 
|

| 
|