Print
Export
Property attributes
Value list
All
<
>
Print
Export
Value list
English
French
German
Japanese
Chinese
PROPERTY
Code:
0112/2///61360_4#AAF152
Version:
001
Revision:
05
IRDI:
0112/2///61360_4#AAF152#001
Preferred name:
input offset current
Synonymous name:
Symbol:
I_IO}
Synonymous symbol:
Short name:
I_IO
Definition:
maximum value of the dc current equal to the difference in the currents in the two input terminals of an operational amplifier to attain zero output voltage at reference conditions
Note:
Remark:
Primary unit:
A
Alternative units:
Level:
max
Data type:
LEVEL(MAX) OF REAL_MEASURE_TYPE
Format:
NR3 S..3.3ES2
Property constraint:
Definition source:
IEC 60748-3 (II.2.1.5) (1986)
Property data element type:
DEPENDENT_P_DET
Drawing:
Formula:
Value list code:
Value list:
DET class:
E01 - electric current
Applicable classes:
0112/2///61360_4#AAA008 - operational amplifier
Definition class:
0112/2///61360_4#AAA001
Code for unit:
0112/2///62720#UAA101 - ampere
Codes for alternative units:
Code for unit list:
Status level:
Standard
Is deprecated:
Published in:
IEC 61360-4
Published by:
IEC
Proposal date:
2015-08-17
Version initiation date:
1996-08-01
Version release date:
2011-08-31
Revision release date:
2015-08-17
Obsolete date:
Responsible Committee:
SC3D
Conditions:
0112/2///61360_4#AAE995 - reference conditions
Change request ID:
Version history:
Version history:
001-05 (2015-08-17 15:40:37 by BATCH 00000917)
standard
PROPRIÉTÉ
Code:
0112/2///61360_4#AAF152
Version:
001
Révision:
05
IRDI:
0112/2///61360_4#AAF152#001
Nom préféré:
Nom synonyme:
Symbole:
I_IO}
Symbole synonyme:
Nom court:
Définition:
Note:
Remarque:
Traducteur:
Version de traduction:
Date de traduction:
Unité primaire:
A
Unités alternatives:
Niveau:
max
Type de données:
LEVEL(MAX) OF REAL_MEASURE_TYPE
Format:
NR3 S..3.3ES2
Property constraint:
Source de définition:
IEC 60748-3 (II.2.1.5) (1986)
Property data element type:
DEPENDENT_P_DET
Dessin:
Formule:
Value list code:
Liste de valeurs:
Classe DET:
E01 - electric current
Classes applicables:
0112/2///61360_4#AAA008 - operational amplifier
Definition class:
0112/2///61360_4#AAA001
Code for unit:
0112/2///62720#UAA101 - ampere
Codes for alternative units:
Code for unit list:
Statut:
Standard
Is deprecated:
Publié dans:
IEC 61360-4
Publié par:
IEC
Date de proposition:
2015-08-17
Version, date d'initialisation:
1996-08-01
Version, date de publication:
2011-08-31
Revision release date:
2015-08-17
Date d'obsolescence:
Responsible Committee:
SC3D
Conditions:
0112/2///61360_4#AAE995 - reference conditions
Change request ID:
Historique:
Historique:
001-05 (2015-08-17 15:40:37 by BATCH 00000917)
standard
MERKMAL
Code:
0112/2///61360_4#AAF152
Version:
001
Revision:
05
IRDI:
0112/2///61360_4#AAF152#001
Bevorzugter Name:
Synonym:
Symbol:
I_IO}
Synonymes Symbol:
Kurzbezeichnung:
Definition:
Notiz:
Bemerkung:
Übersetzer:
Übersetzung, Revision:
Übersetzung, Revisionsdatum:
Empfohlene Einheit:
A
Alternative Einheit(en):
Ebene:
max
Datentyp:
LEVEL(MAX) OF REAL_MEASURE_TYPE
Format:
NR3 S..3.3ES2
Property constraint:
Quelle der Definition:
IEC 60748-3 (II.2.1.5) (1986)
Property data element type:
DEPENDENT_P_DET
Zeichnung:
Formel:
Value list code:
Werteliste:
Geltungsbereich:
E01 - electric current
Anwendbare Klassen:
0112/2///61360_4#AAA008 - operational amplifier
Definition class:
0112/2///61360_4#AAA001
Code for unit:
0112/2///62720#UAA101 - ampere
Codes for alternative units:
Code for unit list:
Status:
Standard
Is deprecated:
Veröffentlicht in:
IEC 61360-4
Veröffentlicht von:
IEC
Datum des Vorschlags:
2015-08-17
Version, Veranlassungsdatum:
1996-08-01
Version, Freigabedatum:
2011-08-31
Revision release date:
2015-08-17
Gestrichen seit:
Responsible Committee:
SC3D
Bedingung(en):
0112/2///61360_4#AAE995 - reference conditions
Change request ID:
Historie:
Historie:
001-05 (2015-08-17 15:40:37 by BATCH 00000917)
standard
プロパティ(属性)
識別コード:
0112/2///61360_4#AAF152
改訂版:
001
修正刷:
05
IRDI:
0112/2///61360_4#AAF152#001
推奨名:
別名:
記号:
I_IO}
同義記号:
略称:
定義:
注記:
備考:
翻訳者:
翻訳第 m 版:
翻訳版発行日:
主用単位:
A
代替単位系:
レベル:
max
データ型:
LEVEL(MAX) OF REAL_MEASURE_TYPE
形式:
NR3 S..3.3ES2
Property constraint:
定義出典:
IEC 60748-3 (II.2.1.5) (1986)
Property data element type:
DEPENDENT_P_DET
図:
数式:
Value list code:
値リスト:
ISO 31 プロパティ分類 :
E01 - electric current
実効クラス:
0112/2///61360_4#AAA008 - operational amplifier
Definition class:
0112/2///61360_4#AAA001
Code for unit:
0112/2///62720#UAA101 - ampere
Codes for alternative units:
Code for unit list:
状態:
標準
Is deprecated:
公開:
IEC 61360-4
公開者:
IEC
提案日時:
2015-08-17
初版作成日:
1996-08-01
改訂版公開日:
2011-08-31
Revision release date:
2015-08-17
廃用期日:
Responsible Committee:
SC3D
条件:
0112/2///61360_4#AAE995 - reference conditions
Change request ID:
版改訂履歴:
版改訂履歴:
001-05 (2015-08-17 15:40:37 by BATCH 00000917)
standard
PROPERTY
代码:
0112/2///61360_4#AAF152
版本号:
001
修订号:
05
IRDI:
0112/2///61360_4#AAF152#001
推荐名:
同义名:
符号:
I_IO}
同义符号:
短名:
定义:
注释:
备注:
Translator (to be translated in Chinese):
Translation revison (to be translated in Chinese):
Translation revision date (to be translated in Chinese):
基本单位:
A
替代单位:
层:
max
Data type:
LEVEL(MAX) OF REAL_MEASURE_TYPE
格式:
NR3 S..3.3ES2
Property constraint:
定义来源:
IEC 60748-3 (II.2.1.5) (1986)
特性数据元素类型:
DEPENDENT_P_DET
图:
公式:
取值列表代码:
取值列表:
DET类:
E01 - electric current
适用类:
0112/2///61360_4#AAA008 - operational amplifier
定义类:
0112/2///61360_4#AAA001
单位代码:
0112/2///62720#UAA101 - ampere
替代单位代码:
单位列表代码:
状态级别:
Standard (to be translated)
Is deprecated:
发布:
IEC 61360-4
发布者:
IEC
提议日期:
2015-08-17
版本生成日期:
1996-08-01
版本发布日期:
2011-08-31
修订发布日期:
2015-08-17
废止日期:
负责委员会:
SC3D
条件:
0112/2///61360_4#AAE995 - reference conditions
变更请求号:
版本历史:
版本历史:
001-05 (2015-08-17 15:40:37 by BATCH 00000917)
standard
Version history
Historique
Historie
版改訂履歴:
版本历史:
001-05 (2015-08-17 15:40:37 by BATCH 00000917)
standard
.....
001-04 (2015-07-23 11:08:30 by BATCH 00000907)
superseded
001-03 (2015-07-22 14:21:37 by BATCH 00000904)
superseded
001-02 (2012-05-30 15:03:36 by BATCH 00000788)
superseded
001-01 (2012-05-30 14:53:56 by BATCH 00000787)
superseded
Web page created
2025-01-11
Copyright ©
2025
IEC
, Geneva, Switzerland. All rights reserved