IEVref:845-29-074ID:
Language:enStatus: Standard
Term: ceiling cavity ratio
Synonym1:
Synonym2:
Synonym3:
Symbol: Kc
K
Definition: quotient of five times the sum of the area of the walls bounded by the ceiling and the plane of the luminaires and the sum of the areas of the ceiling and the plane of the luminaires, used in the calculation of the utilization factor or utilance

Note 1 to entry: The ceiling cavity ratio is given by the formula

K c = 5 h c (a+b) ab MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX garuavP1wzZbItLDhis9wBH5garmWu51MyVXgaruWqVvNCPvMCG4uz 3bqee0evGueE0jxyaibaieYdi9WrpeeC0lXdh9vqqj=hEeea0xXdbb a9frFj0=OqFfea0dXdd9vqaq=JfrVkFHe9pgea0dXdar=Jb9hs0dXd bPYxe9vr0=vr0=vqpWqaaeaaciWacmGadaGadeaaeaGaauaaaOqaai aadUeadaWgaaWcbaGaae4yaaqabaGccqGH9aqpdaWcaaqaaiaaiwda caWGObWaaSbaaSqaaiaabogaaeqaaOGaaGjbVlaacIcacaWGHbGaey 4kaSIaamOyaiaacMcaaeaacaWGHbGaaGPaVlaadkgaaaaaaa@45D0@

where a and b are the dimensions of the sides of the room and hc is the distance from the ceiling to the plane of the luminaires.

Note 2 to entry: See also "floor cavity ratio" and "room cavity ratio".

Note 3 to entry: The ceiling cavity ratio has unit one.