Language:enStatus: Standard
Term: room cavity ratio
Synonym1:
Synonym2:
Synonym3:
Symbol: K
Definition: quotient of five times the sum of the area of the walls bounded by the working plane and the plane of the luminaires and the sum of the areas of the working plane and the plane of the luminaires, used in the calculation of the utilization factor or utilance

Note 1 to entry: The room cavity ratio is expressed by the formula

K= 5h( a+b ) ab MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX garuavP1wzZbItLDhis9wBH5garmWu51MyVXgaruWqVvNCPvMCG4uz 3bqee0evGueE0jxyaibaieYdi9WrpeeC0lXdh9vqqj=hEeea0xXdbb a9frFj0=OqFfea0dXdd9vqaq=JfrVkFHe9pgea0dXdar=Jb9hs0dXd bPYxe9vr0=vr0=vqpWqaaeaaciWacmGadaGadeaaeaGaauaaaOqaai aadUeacqGH9aqpdaWcaaqaaiaaiwdacaWGObWaaeWaaeaacaWGHbGa ey4kaSIaamOyaaGaayjkaiaawMcaaaqaaiaadggacaaMc8UaamOyaa aaaaa@423B@

where a and b are the dimensions of the sides of the room and h the mounting height, that is the distance between the working plane and the plane of the luminaires.

Note 2 to entry: See also "ceiling cavity ratio" and "floor cavity ratio".

Note 3 to entry: The room cavity ratio has unit one.