Definition: | output Boolean variable issued by the controlling system described by the function chart SEE Figure 23. Note 1 to entry: Various types of commands, such as not stored command, stored command, delayed command, time-limited command, conditional command and their combination are defined in IEC 60848, GRAFCET specification language for sequential function charts, and are identified by a conventional letter. Note 2 to entry: This entry was numbered 351-29-31 in IEC 60050-351:2006.
|