power dissipated in a composite superconductor owing to the application of a time-varying magnetic field or electric current
Note 1 to entry: AC loss includes time-averaged hysteresis loss of the superconductor, a coupling current loss and an eddy current loss of the conductor, and an eddy current loss of the structural material. Note 2 to entry: AC loss customarily also includes the power dissipated in the normal matrix of a superconductor or the structural material owing to the application of transient changes in magnetic field or current. Note 3 to entry: This entry was numbered 815-13-52 in IEC 60050-815:2015.
|