Queries, comments, suggestions? Please contact us.



Area: 314: Electrical and electronic measurements - Specific terms according to the type of instrument           Index language:

Hide details for [<u>Section 314-01: Analogue instruments</u>]Section 314-01: Analogue instruments
314-01-01
index (of an indicating device)
314-01-02
scale (of an analogue measuring instrument)
314-01-03
dial
314-01-04
scale marking
314-01-05
scale mark
314-01-06
scale numbering
314-01-07
scale length
314-01-08
scale division
314-01-09
scale spacing
314-01-10
scale interval
314-01-11
pointer instrument
314-01-12
instrument with optical index
314-01-13
moving-scale instrument
314-01-14
shadow column instrument
314-01-15
electrostatic instrument
314-01-16
(permanent magnet) moving-coil instrument
314-01-17
moving magnet instrument
314-01-18
moving-iron instrument
314-01-19
electrodynamic instrument
314-01-20
ferrodynamic instrument
314-01-21
induction instrument
Hide details for [<u>Section 314-02: Digital instruments</u>]Section 314-02: Digital instruments
314-02-01
analogue to digital conversion (for measuring instruments)
314-02-02
digital to analogue conversion (for measuring instruments)
314-02-03
scaling (for analogue-to-digital conversion)
314-02-04
linear conversion
314-02-05
non-linear conversion
314-02-06
conversion rate
314-02-07
(total) conversion time
314-02-08
readout time
314-02-09
overflow
314-02-10
output state
314-02-11
representation unit
314-02-12
code converter
Hide details for [<u>Section 314-03: Recorders</u>]Section 314-03: Recorders
314-03-01
recording
314-03-02
recording medium
314-03-03
recording chart
Hide details for [<u>Section 314-04: Transducers</u>]Section 314-04: Transducers
314-04-01
measuring element of a transducer
314-04-02
conversion coefficient
314-04-03
(output) span
314-04-04
measuring range (of a transducer)
314-04-05
maximum permissible values of the input current and voltage
314-04-06
output signal
314-04-07
output current
314-04-08
reversible output current
314-04-09
limiting value of the output current
314-04-10
compliance voltage
Hide details for [<u>Section 314-05: Stabilized power supplies</u>]Section 314-05: Stabilized power supplies
314-05-01
closed loop stabilization
314-05-02
open loop stabilization
314-05-03
slave operation
314-05-04
slave tracking operation
314-05-05
parallel operation
314-05-06
series operation
314-05-07
stabilized load characteristic
314-05-08
crossover of load characteristic
314-05-09
constant voltage to constant current crossover
Hide details for [<u>Section 314-06: Oscilloscopes</u>]Section 314-06: Oscilloscopes
314-06-01
deflection coefficient
314-06-02
time base
314-06-03
sweep
314-06-04
free-running time base
314-06-05
triggered time base
314-06-06
trigger hold off
314-06-07
single sweep operation
314-06-08
sweep coefficient
314-06-09
sweep rate
314-06-10
sweep expansion
314-06-11
synchronized sweep
314-06-12
triggered sweep
314-06-13
internal triggering
314-06-14
internal synchronization
314-06-15
external triggering
314-06-16
external synchronization
314-06-17
time base jitter
Hide details for [<u>Section 314-07: Energy meters</u>]Section 314-07: Energy meters
314-07-01
basic current
314-07-02
rated current
314-07-03
maximum current
314-07-04
reference voltage
314-07-05
reference frequency
314-07-06
class index (of an energy meter)
314-07-07
meter type
314-07-08
(meter) constant
314-07-09
register
314-07-10
memory (for static meters)
314-07-11
display (for static meters)
314-07-12
test output device (of an energy meter)
314-07-13
operation indicator
314-07-14
base (of an energy meter)
314-07-15
socket (of an energy meter)
314-07-16
cover (of an energy meter)
314-07-17
case (of an energy meter)
314-07-18
terminal block
314-07-19
terminal cover
314-07-20
indoor meter
314-07-21
outdoor meter
Hide details for [<u>Section 314-08: Signal generators</u>]Section 314-08: Signal generators
314-08-01
amplitude modulation
314-08-02
frequency modulation
314-08-03
phase modulation
314-08-04
amplitude modulation factor
314-08-05
envelope of an amplitude modulated signal
314-08-06
amplitude modulation distortion
314-08-07
(absolute) frequency deviation
314-08-08
frequency modulation distortion
314-08-09
carrier frequency shift
314-08-10
frequency range
314-08-11
frequency band, <of a signal generator>
314-08-12
band overlap
314-08-13
matched output voltage
314-08-14
source e.m.f.
314-08-15
maximum output power
Hide details for [<u>Section 314-09: Measuring bridges</u>]Section 314-09: Measuring bridges
314-09-01
range-changing device
314-09-02
range factor
314-09-03
measuring dial
314-09-04
dial setting
314-09-05
connecting resistance (potential)
314-09-06
link resistance (current)


Copyright © IEC 2024. All Rights Reserved.